The question
How should tubes, box sections and other hollow steelwork be detailed if they are to be hot-dip galvanized after fabrication?
Short answer
Every enclosed space has to let air out and let cleaning solutions and molten zinc flow in, over and back out. That means planned vent and drain openings at the high and low points for the way the piece is dipped, interconnected internal passages and no sealed voids. It is a safety issue as well as a finish issue: liquid trapped in a closed connection can turn to superheated steam on immersion. Agree hole positions and sizes with the galvanizer for the actual piece.1
Why venting matters
Hot-dip galvanizing is a total immersion process. Cleaning solutions must reach and wet every surface of a hollow fabrication, and no solution should remain trapped inside when it is withdrawn.2
The American Galvanizers Association gives two reasons for vent and drain holes. The primary reason is to let air escape so the piece can be completely immersed in the cleaning solutions and the molten zinc. The secondary reason is to prevent damage: pickling solution or rinse water trapped in a blind or closed connection can turn to superheated steam or gas and develop very high pressure when immersed, which can damage the fabrication and put galvanizing personnel and equipment at risk.1
Where the openings go
Pieces are dipped and withdrawn at an angle, so vents are located at the highest point and drains at the lowest. Fabricated pipework should be interconnected with full open tee or mitre joints, each enclosed section needs a vent at each end, and tubular structures are best submerged completely in one dip.1
Many galvanizers prefer venting that is visible from the outside so they can confirm it is adequate and has not been omitted, and some may hesitate to process complex pipe assemblies without it.1
Base plates and end plates should be designed for venting and draining. Cutting the plate fully open gives the least obstruction; where that is not possible, vent holes in the plate are the usual solution. Holes can be left open or plugged after galvanizing. The guide notes aluminium plugs for mild and moderate environments and zinc plugs for more corrosive ones, to avoid galvanic corrosion.1
The AGA guide illustrates recommended arrangements for handrail, tube and pipe trusses, pipe columns, box sections and similar items, and states minimum vent dimensions for those arrangements.3
Practical consideration
We have not reproduced hole sizes. They depend on the section, its length, how it will be hung and the galvanizer’s equipment, and an opening in a structural member is also a structural question for the designer.
- Vent at the highest point in the dipping position
- Drain at the lowest point
- Internal openings at joints so every cell connects
- End or base plate cut open or vented
- Vents visible from outside for the galvanizer to check
Enclosed, overlapping and sealed details
For tanks and enclosed items galvanized inside and out, solutions and zinc should enter at the bottom and air should leave through an opening at the highest point, with at least one fill or drain hole and one vent. The guide recommends reviewing drawings of enclosed or partly enclosed items with the galvanizer before fabrication.4
Narrow gaps, overlapping plates and back-to-back angles or channels are best avoided. Where a tight overlap cannot be avoided, the guide recommends sealing all edges by welding, because zinc will not enter the gap but cleaning solutions will and can later weep out as rust staining. A sealed weld must be free of pinholes, and larger sealed overlaps need vent holes; the guide tabulates vent sizes by overlap area.5
Practical consideration
The guide describes the choice between a fully sealed joint and a skip-welded one as a trade-off to settle with the galvanizer. The weld pattern also has to satisfy the structural design of the joint.
Distortion, welds and material
Steel is heated to about 443 °C during galvanizing, and every heating and cooling cycle adds stress to a fabrication. Kettle size limits what can be dipped in one go, so dimensions should be checked with the galvanizer early and large items designed in modules where needed.6
To limit distortion the guide recommends parts of similar thickness at joints, symmetrical sections where possible, a balanced welding sequence, temporary bracing on thin or asymmetric work, and optimised venting, drainage and lifting points on long, slender products.7
There is a small potential for cracking at flame-cut beam copes and at the corners of rectangular hollow sections. The guide recommends visual inspection after galvanizing and repair and touch-up before delivery.8
Welding flux residues are not removed by the galvanizer’s chemical cleaning and must be removed beforehand, and high-silicon weld metal can produce a thicker, darker coating over the weld.9 Steel chemistry, particularly silicon and phosphorus, affects coating thickness and appearance, so the galvanizer should know the steel grade.10
Agree with the galvanizer before fabrication
- Maximum piece size and weight for their kettle and handling
- Dipping orientation and lifting points
- Vent and drain positions and sizes on the shop drawings
- Treatment of overlaps, seal welds and any enclosed cells
- Steel grades and weld consumables
- Whether vents are plugged afterwards, and with what
A working list for shop-drawing review. It is not a specification.
Scope and limits
The AGA guide is US industry guidance and refers to ASTM practices. It presents itself as general information, not a substitute for competent professional examination of a specific item.11
Practical consideration
A project may specify other galvanizing standards, so the coating requirement follows the project specification. This guide covers detailing for the process, not the structural design of the member.
Questions this guide answers
Source notes
Numbered notes point to the exact section and physical PDF page. Page numbers are the PDF viewer’s page, which can differ from the number printed on the page. Sources checked 23 September 2026. These notes support the statements; they are not a substitute for reading the current document for a project.
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Venting tubular fabrications and hollow structurals, continued, Figures 18 and 19 (printed page 11), PDF page 13. Open the publisher PDF at page 13 (opens in a new tab) ↩ ↩ ↩ ↩ ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Allowing for proper drainage; venting tubular fabrications and hollow structurals (printed page 10), PDF page 12. Open the publisher PDF at page 12 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Recommended designs for tubular fabrications and hollow structures, opening paragraph and handrail (printed page 12; item list in the contents, printed page 1), PDF page 14. Open the publisher PDF at page 14 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Proper venting and drainage of enclosed and semi-enclosed fabrications (printed page 16), PDF page 18. Open the publisher PDF at page 18 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Precautions for overlapping and contacting surfaces, Table 2 (printed page 17), PDF page 19. Open the publisher PDF at page 19 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Size and shape; process temperature and heat (printed page 5), PDF page 7. Open the publisher PDF at page 7 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Tips for minimizing distortion (printed page 9), PDF page 11. Open the publisher PDF at page 11 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Cope cuts; inspection of HSS corners (printed page 7), PDF page 9. Open the publisher PDF at page 9 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Welding procedures and welding flux removal (printed page 18), PDF page 20. Open the publisher PDF at page 20 (opens in a new tab) ↩
Design of Products to Be Hot-Dip Galvanized After Fabrication, Copyright 2023, as printed in the acquired PDF. American Galvanizers Association. Materials suitable for galvanizing (printed page 3), PDF page 5. Open the publisher PDF at page 5 (opens in a new tab) ↩